Thermopile

From KYNNpedia
Revision as of 00:40, 7 October 2023 by imported>HTinC23 (added Category:Thermoelectricity using HotCat)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Diagram of a differential temperature thermopile with two sets of thermocouple pairs connected in series. The two top thermocouple junctions are at temperature T1 while the two bottom thermocouple junctions are at temperature T2. The output voltage from the thermopile, ΔV, is directly proportional to the temperature differential, ΔT or T1 - T2, across the thermal resistance layer and number of thermocouple junction pairs. The thermopile voltage output is also directly proportional to the heat flux, q", through the thermal resistance layer.
Picture of a heat flux sensor that utilizes a thermopile construction to directly measure heat flux. Model shown is the FluxTeq PHFS-01 heat flux sensor. Voltage output is passively induced from the thermopile proportional to the heat flux through the sensor or similarly the temperature difference across the thin-film substrate and number of thermocouple junction pairs. This voltage output from the sensor's thermopile is initially calibrated in order to relate it to heat flux.

A thermopile is an electronic device that converts thermal energy into electrical energy.<ref name=":0">"Woodhead Publishing Series in Energy", Advances in Solar Heating and Cooling, Elsevier, 2016, pp. xiii–xviii, doi:10.1016/b978-0-08-100301-5.09002-0, ISBN 9780081003015</ref> It is composed of several thermocouples connected usually in series or, less commonly, in parallel. Such a device works on the principle of the thermoelectric effect, i.e., generating a voltage when its dissimilar metals (thermocouples) are exposed to a temperature difference.<ref name=":0" />

Thermocouples operate by measuring the temperature differential from their junction point to the point in which the thermocouple output voltage is measured. Once a closed circuit is made up of more than one metal and there is a difference in temperature between junctions and points of transition from one metal to another, a current is produced as if generated by a difference of potential between the hot and cold junction.<ref>Adams, Charles Kendall (1895). Johnson's Universal Cyclopedia: A New Edition. D. Appleton, A. J. Johnson. p. 116.</ref>

Thermocouples can be connected in series as thermocouple pairs with a junction located on either side of a thermal resistance layer. The output from the thermocouple pair will be a voltage that is directly proportional to the temperature difference across the thermal resistance layer and also to the heat flux through the thermal resistance layer. Adding more thermocouple pairs in series increases the magnitude of the voltage output. Thermopiles can be constructed with a single thermocouple pair, composed of two thermocouple junctions, or multiple thermocouple pairs.

Thermopiles do not respond to absolute temperature, but generate an output voltage proportional to a local temperature difference or temperature gradient. The amount of voltage and power are very small and they are measured in milli-watts and milli-volts using controlled devices that are specifically designed for such purpose.<ref>Montgomery, Ross; McDowall, Robert (2008). Fundamentals of HVAC Control Systems. Atlanta: Elsevier. p. 161. ISBN 9780080552330.</ref>

Thermopiles are used to provide an output in response to temperature as part of a temperature measuring device, such as the infrared thermometers widely used by medical professionals to measure body temperature, or in thermal accelerometers to measure the temperature profile inside the sealed cavity of the sensor.<ref>Mukherjee, Rahul; Basu, Joydeep; Mandal, Pradip; Guha, Prasanta Kumar (2017). "A review of micromachined thermal accelerometers". Journal of Micromechanics and Microengineering. 27 (12): 123002. arXiv:1801.07297. Bibcode:2017JMiMi..27l3002M. doi:10.1088/1361-6439/aa964d. S2CID 116232359.</ref> They are also used widely in heat flux sensors and pyrheliometers<ref>"Glossary of Meteorological Terms (T) - NovaLynx Corporation". Retrieved 17 November 2016.</ref><ref>"Glossary". Retrieved 17 November 2016.</ref> and gas burner safety controls. The output of a thermopile is usually in the range of tens or hundreds of millivolts.<ref>"Glossary". Archived from the original on 3 March 2016. Retrieved 17 November 2016.</ref> As well as increasing the signal level, the device may be used to provide spatial temperature averaging.<ref>"Capgo - Sensor Glossary". Retrieved 17 November 2016.</ref>

Thermopile, composed of multiple thermocouples in series. If both the right and left junctions are the same temperature, voltages cancel out to zero. However, if there is a temperature difference between sides the resulting total output voltage is equal to the sum of junction voltage differentials.

Thermopiles are also used to generate electrical energy from, for instance, heat from electrical components, solar wind, radioactive materials, laser radiation or combustion. The process is also an example of the Peltier effect (electric current transferring heat energy) as the process transfers heat from the hot to the cold junctions.

There are also the so-called thermopile sensors, which are power meters based on the principle that the optical or laser power is converted to heat and the resulting increase in temperature is measured by a thermopile.<ref>Pineda, Diana Davila; Rezaniakolaei, Alireza (2017-08-22). Thermoelectric Energy Conversion: Basic Concepts and Device Applications. Hoboken, NJ: John Wiley & Sons. ISBN 9783527698134.</ref>

See also

  • Seebeck effect, the physical effect responsible for the generation of voltage in a thermopile
  • Thermoelectric materials, high-performance materials that can be used to construct a compact thermopile that delivers high power

References

<references group="" responsive="1"></references>

External links