Description
English: A coal-fired thermal power station.

Key

Coal is conveyed (14) from an external stack and ground to a very fine powder by large metal spheres in the pulverised fuel mill (16). There it is mixed with preheated air (24) driven by the forced draught fan (20). The hot air-fuel mixture is forced at high pressure into the boiler where it rapidly ignites. Water of a high purity flows vertically up the tube-lined walls of the boiler, where it turns into steam, and is passed to the boiler drum (17), where steam is separated from any remaining water. The steam passes through a manifold in the roof of the drum into the pendant superheater (19) where its temperature and pressure increase rapidly to around 200 bar and 570°C, sufficient to make the tube walls glow a dull red. The steam is piped to the high pressure turbine (11), the first of a three-stage turbine process. A steam governor valve (10) allows for both manual control of the turbine and automatic set-point following. The steam is exhausted from the high pressure turbine, and reduced in both pressure and temperature, is returned to the boiler reheater (21). The reheated steam is then passed to the intermediate pressure turbine (9), and from there passed directly to the low pressure set (6). The steam, now little above its boiling point, is brought into thermal contact with cold water in the condensor (8), where it condenses rapidly back into water, creating a near vacuum inside the condensor chest. The condensed water is then passed by a feed pump (7) through a deaerator (12), and pre-warmed, first in a feed heater (13) powered by steam drawn from the high pressure set, and then in the economiser (23), before being returned to the boiler drum. The water from the condensor is sprayed inside a cooling tower (1), creating a highly visible plume, before being pumped back to the cooling water cycle.

The three turbine sets are coupled on the same shaft as the electrical generator (5) which generates an intermediate level voltage (typically 20-25 kV). This is stepped up by the unit transformer (4) to a voltage more suitable for transmission (typically 250-500 kV) and is sent out onto the transmission system (3).

Exhaust gas from the boiler is drawn by the induced draft fan (26) through an electrostatic precipitator (25) and is then vented through the chimney stack (27).

A version of this image without the integrated key is at en:Image:PowerStation2.svg.

References

  • (1982) Modern Power Station Practice, vol 1:Planning & Layout; vol 2:Boilers, Fuel & Ash-handling plant; vol 3: Turbines & Auxiliary Equipment, Oxford: Pergamon. ISBN 0-08-016436-6.
  • RWE npower Didcot Power Stations
  • Drax Power Ltd How Drax works
Date 24 June 2006 (original upload date)
Source Transferred from en.wikipedia to Commons.
Author BillC at English Wikipedia
SVG development
InfoField
 
The SVG code is valid.
 
This diagram was created with Adobe Illustrator.
 
 This diagram uses embedded text that can be easily translated using a text editor.

Licensing

BillC at English Wikipedia, the copyright holder of this work, hereby publishes it under the following license:
GNU head Permission is granted to copy, distribute and/or modify this document under the terms of the GNU Free Documentation License, Version 1.2 or any later version published by the Free Software Foundation; with no Invariant Sections, no Front-Cover Texts, and no Back-Cover Texts. A copy of the license is included in the section entitled GNU Free Documentation License.
w:en:Creative Commons
attribution share alike
This file is licensed under the Creative Commons Attribution-Share Alike 3.0 Unported license.
Attribution: BillC at English Wikipedia
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
  • share alike – If you remix, transform, or build upon the material, you must distribute your contributions under the same or compatible license as the original.
This licensing tag was added to this file as part of the GFDL licensing update.

Original upload log

The original description page was here. All following user names refer to en.wikipedia.
  • 2006-07-14 22:13 BillC 3000×2063×0 (473486 bytes) Larger key
  • 2006-06-24 08:25 BillC 3000×2063×0 (473455 bytes) Larger key text
  • 2006-06-24 08:18 BillC 3000×2063×0 (473049 bytes) Coal-fired thermal power station.

Assessment

Wikipedia

 This is a featured picture on the English language Wikipedia (Featured pictures) and is considered one of the finest images. See its nomination here.

If you think this file should be featured on Wikimedia Commons as well, feel free to nominate it.
If you have an image of similar quality that can be published under a suitable copyright license, be sure to upload it, tag it, and nominate it.


Annotations
InfoField
This image is annotated: View the annotations at Commons

Captions

Add a one-line explanation of what this file represents

24 June 2006

image/svg+xml

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current22:57, 25 November 2021Thumbnail for version as of 22:57, 25 November 2021512 × 358 (166 KB)wikimediacommons>Puck04fixed SVG code (was "W3C-invalid") + cleanup using text editor

The following page uses this file:

Metadata