File:T ratings oldest trick in the book 006.png

From KYNNpedia

Original file(7,202 × 5,992 pixels, file size: 2.58 MB, MIME type: image/png)

This file is from Wikimedia Commons and may be used by other projects. The description on its file description page there is shown below.

Summary

Description
English: Close-up of bus duct with 2 layers of Mylar wrappings. These overlap and are held together with Scotch tape. These wrappings are "rated to 130°C", which is fairly useless in a building fire or fire testing as These can go up to 1100°C, where the wrapping catch on fire, which spreads, along with smoke and heat, through the inside of the bis duct, to the unexposed side (in the test lab) or, worse, an unengaged fire compartment.
Deutsch: Nahaufnahme einer Stromschiene mit doppelter Plastikumwicklung. Diese Umhüllung besteht aus Mylar, welches bis zu einer Temperatur von 130°C zugelassen ist. Diese Temperaturgrenze ist unzureichend für Gebäudefeuer oder Brandprüfungen, wo Temperaturen bis zu 1100°C erreicht werden. Wenn innerhalb des Stromschienenkastens keine Abschottung seitens des Herstellers eingesetzt wird, brennen diese Plastikumhüllungen an der äußeren Abschottung vorbei und in die abgewandte Seite hinein - nebst Hitze und Rauch.
Date
Source Own work
Author Achim Hering

Licensing

I, the copyright holder of this work, hereby publish it under the following license:
w:en:Creative Commons
attribution
This file is licensed under the Creative Commons Attribution 4.0 International license.
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.

Captions

Add a one-line explanation of what this file represents

Items portrayed in this file

depicts

8 August 2012

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current02:04, 29 September 2015Thumbnail for version as of 02:04, 29 September 20157,202 × 5,992 (2.58 MB)wikimediacommons>Achim Hering{{Information |Description ={{en|1=Close-up of bus duct with 2 layers of Mylar wrappings. These overlap and are held together with Scotch tape. These wrappings are "rated to 130°C", which is fairly useless in a building fire or fire testing as Thes...

The following page uses this file: