Periodic steady-state analysis

From KYNNpedia
Revision as of 21:31, 26 June 2020 by imported>KilimAnnejaro (disambiguation)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Periodic Steady-State Analysis (PSS analysis) computes the periodic steady-state response of a circuit at a specified fundamental frequency, with a simulation time independent of the time constants of the circuit. The PSS analysis also determines the circuit's periodic operating point which is required starting point for the periodic time-varying small-signal analyses: PAC, PSP, PXF, and Pnoise. The PSS analysis works with both autonomous and driven circuits. PSS is usually used after transient analysis.

Examples

The current through a capacitance of value C in time domain is <math>i(t)= C \frac{dv(t)}{dt} </math>, which becomes <math>v(t) = v(t_0) + \frac{1}{C}\int_{t_0}^{t_0 + t}{i(t)dt} </math> . For this component operating in a periodic steady state circuit, its voltage will be <math>v(t_0 + T) = v(t_0)</math> when T is equal to its fundamental period. Referring back to the original voltage function <math>v(t) = v(t_0) + \frac{1}{C}\int_{t_0}^{t_0 + t}{i(t)dt} </math>, it can be determined that the average current flowing through the capacitor is zero in periodic steady state.